2.2 Important safety instructions
The device has been designed and tested strictly according to the international safety requirements. As with all electrical or
electronical devices, there are residual risks despite careful construction. To prevent personal injury and property damage
and to ensure long-term operation of the device, read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to high voltages of the PV array or the battery!
The DC cables connected to the battery or the PV array may be live. Touching the DC conductors or the live
components can cause to lethal electric shocks. If you disconnect the DC connectors from the device under
load, an electric arc may occur leading to electric shock and burns.
Do not touch non-insulated cable ends.
Do not touch the DC conductors.
Do not touch any live components of the device.
Do not open the device.
Observe all safety information of the battery manufacturer.
All work on the device must only be carried out by qualified personnel who have read and fully
understood all safety information contained in this document and the user manual.
Disconnect the device from all voltage and energy sources and ensure it cannot be reconnected
before working on the device.
Wear suitable personal protective equipment for all work on the device.
DANGER
Danger to life due to electric shock when touching live components in backup mode!
Even if the AC breaker and the PV switch of the inverter are disconnected, the parts of the system may still
be live when the battery is switched on due to backup mode.
Do not open the device.
Disconnect the device from all voltage and energy sources and ensure it can not be reconnected
before working on the device.
DANGER
Danger to life due to fire or explosion when batteries are fully discharged!
A fire may occur due to incorrect charging of fully discharged batteries. This can result in death or serious
injury.
Make sure that the battery is not fully discharged before commissioning the system.
Contact the battery manufacturer for further proceedings if the battery is fully discharged.
DANGER
Danger to life due to burns caused by electric arcs through short-circuit currents!
Short-circuit currents in the battery can cause heat accumulation and electric arcs if the battery is short
circuited or wrongly installed. Heat accumulation and electric arcs may result in lethal injuries due to burns.
Disconnect the battery from all voltages sources prior to performing any work on the battery.
Only use properly insulated tools to prevent accidental electric shock or short circuits during
installation.
Observe all safety information of the battery manufacturer.
Page 6
KACO blueplanet hybrid 6.0 NH3 M2 KACO blueplanet hybrid 8.0 NH3 M3 KACO blueplanet hybrid 10.0 NH3 M3 KACO blueplanet hybrid 12.0 NH3 M3