DANGER: This product isnotintended fordamage control orto deal w ithflooding result
ingfromhulldamage. This productis i ntended t o beused inBilgePumping S ystems forsmall
craft w itha hulllength upto 24meters, asdescribed withintheintroduction andscope of ISO
15083.Bilge Pumping Systems, asspecified i nISO 15083, a relimited to normal a mounts o f
water inanintact b oatdueto spray, rain, s eepage, spillage, andoccasional small a mounts o f
water s hipped f romboatmovements inheavy w eather. Use ofproduct inanyother waycould
result inflooding, catastrophic
WARNING: This pumpisdesigned f oruse withfresh water a ndsalt w ater O NLY. Use with
anyother hazardous, caustic, orcorrosive material could result i ndamage tothepumpand
thesurrounding environment, possible e xposure to hazardous substances andinjury
WARNING:
Check t hefunctionof all bilgepumpsat regular i ntervals. C lear p ump
inletsfromdebris.If seacocks arefittedin theforeandaftpeak bulkheads, theyshallbe
keptclosed andshallonlybeopened to letwaterdrainintothemainbilges.
RuleMate Intelligence
RuleMate B ilgepumps have built-inprogramming thatcansense whenthepumpis runningbut
notpumping water t o protect thepump, v essel, andthevessel's batteries. If debris foulsthesensor
orthepumpbecomes air-bound, thepumpwillstoprunningandbegin to "check" forwater every
2 1/2 minutes. Once thedebris isremoved, thepumpwill revert to its normal o peration, turningon
whenthewater reaches approximately 2 1/2" andshutting offat 5/8".
OurRuleMatebi gepumpscontain afail-safe back-up program that measures the amountof
workthe motoris performing andthe lengthof timethe motoris running.If debris, s uchas
a wet paper t owelor leaves, b ecame lodgedagainst t he pump,it could"trick"the pumpinto
thinkingwater remained inthe bilgewhichcoud deplete thevessel's b attery.
If the circuitboardsenses t he motoris runningbutdoinq little work(notpumpingwater) f or
longer t hanfifteen seconds, thepump willenter i ntoacycling mode inthesame f ashion asthe
computerized p umps. T hepumpwill sense water every 2.5minutes andif it senses w ater, i twill
continue to rununtilthewaterhasbeenremoved f romthebilge.
Afterthedebrisisremoved, thepumpwill automatically r evert t o the level s ensing mode.
6
damage tocraft, serious personal injury, ordeath.