USER MANUAL
CONNECTIONS AND OPERATING/DISPLAY ELEMENTS – BACK
5. LIFT / GND A – LIFT / GND B – LIFT / GND A+B
Switch for disconnecting the ground connection between the corresponding channel's input and output (ground
lift). The ground connection is disconnected in the unpressed position; the connection is established when the
switch is pressed. The ability to prevent a humming loop using the ground lift switch depends on the grounding of
the connected devices. It is therefore possible that either switch position effectively reduces or eliminates humming.
6. OUTPUT A/OUTPUT B
Balanced audio output with male three-pin XLR sockets. Use a balanced, shielded cable (for example, micro-
phone cable) in order connect the DI box to a mixer's or audio interface's balanced output.
7. OUTPUT A+B
Balanced audio output with male three-pin XLR socket. Channel A and B signals are mono summed here. Use a
balanced, shielded cable (for example, microphone cable) in order connect the DI box to a mixer's or audio inter-
face's balanced output.
ATTENTION: Connecting signal cables can cause significant interference noise. Make sure that devices
connected to the output channel (mixer, audio interface, etc.) and the THRU output are muted while
making connections. Otherwise, noise levels may cause damage.
PLEASE NOTE
The line outputs on the front and rear are galvanically isolated from the line inputs.
If several line outputs are used simultaneously on one channel, the signal level may be slightly reduced.