Continuous operation
To operate the device in continuous operation (CNT), press the "CNT" key.
If the device is working in continuous operation, the corresponding "CNT" LED lights up.
To switch from continuous operation back to automatic operation, press the "CNT" key. The
"CNT" LED goes out.
During operation, the current humidity is shown on the display.
In continuous operation, the unit dehumidifies until it is manually switched off or a set runtime
has expired.
:
Timer
Press the timer key to start the timer function. By repeatedly pressing the plus or minus key,
you can set a time from 1-24 hours. If the timer is activated, this is indicated by the
associated LED.
If you activate the timer during operation, the device switches off after the set time.
If you activate the timer while the device is in standby mode, the device will start
automatically after the set time has elapsed.
If the timer is active, the "Timer" LED lights up.
To switch off the timer, press the timer key again.
Temperature display
Press and hold the timer key for at least 3 seconds and the current room temperature is shown
on the display. After approx. 10 seconds, the current room humidity is displayed again.
Drainage pump:
When the water pump is full, the water pump switches on automatically. The "Pump full"
indicator lights up red. After 30 seconds, the water pump stops working and the "Pump full"
indicator goes out. Press the DRAIN button to pump out the water even if the pump is not yet
full. The pump will then operate for 30 seconds and the "Pump Full" indicator will turn on and
off accordingly.
EN-13