5.3.2.- Coffee dosage setting.
Time controlled Izaga-KEY
The coffee dose is calculated by an electronic timer so the units used are
seconds. The grinder is set at the factory for a grinding time of 1.8 seconds
for 1 cup of coffee and 3.1 seconds for 2 cups of coffee.
Gravimetric model Izaga-W
The coffee dose of the IZAGA-W grinder is controlled by a weight sensor
located inside the grinder, the units used are grams. The factory settings are
8 grams for 1 coffee and 14 g for 2 coffees.
If the dose obtained is not what you want in your coffee machine, modify
the dose as follows:
.
Press the 1 cup key (Pos. F) for 1.5 seconds until the message "C1: 1.80"
appears on screen.
.
Press the keys – or + (Pos. B, C) until reaching the desired value.
.
Press the 1 cup key again to confirm the new dose.
.
Perform the same operation with the 2 cup key (Pos. G).
Note: Program in first place the dose for 1 cup. Notice that the dose for 2
cups is limited to double of the programmed dose for 1 cup.
37