seko POOL BASIC EVO Handbuch Seite 7

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time =100%)
Flow Rate
System Error
Calibration Function
Default parameters:
Language = UK
Set Point value= 7,4 pH; 750 mV (Rx)
Dosing Method = Acid; Low (Rx)
Time OFA = OFF
Calibration = Full
Flow Input= OFF
Type dosing= PROP
0000136904
All manuals and user guides at all-guides.com
enter
cal
prog
esc
set
Display
level____7,2_ph
ofa_alarm__7,2_ph
ofa_stop___7,2_ph
Flow_______7,2_ph
Parameter_error  
Error_7_ph
Error_4_ph  
Error_465_mv  
To restore Default parameters run Following steps:
Power off Pool Basic unit
Keeping Press UP and DOWN Key switch on the
Power.
The unit will flash
Press up
Enter Key to restore Default parameters.
rev. 2.0
Relay
Actions to do
Alarm Relay Close
- Push Enter Key to open
Alarm Relay
- Restore Product tank
Alarm Relay open
- Push Enter Key to reset
Alarm Relay Close
- Push Enter Key to reset
Alarm Relay open
- Restore Flow Rate
Alarm Relay Open
- Press Enter Key to replace
Default parameter
- Destroy Unit
Alarm Relay open
- Restore Probe or Buffer
solution and repeat calibration
function
Init.default__no
Init.default__Yes
6