Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time =100%)
Flow Rate
System Error
Calibration Function
Default parameters:
Language = UK
•
Set Point value= 7,4 pH; 750 mV (Rx)
•
Dosing Method = Acid; Low (Rx)
•
Time OFA = OFF
•
Calibration = Full
•
Flow Input= OFF
•
Type dosing= PROP
•
0000136904
All manuals and user guides at all-guides.com
enter
cal
prog
esc
set
Display
level____7,2_ph
ofa_alarm__7,2_ph
ofa_stop___7,2_ph
Flow_______7,2_ph
Parameter_error
Error_7_ph
Error_4_ph
Error_465_mv
To restore Default parameters run Following steps:
Power off Pool Basic unit
•
Keeping Press UP and DOWN Key switch on the
•
Power.
The unit will flash
•
Press up
•
Enter Key to restore Default parameters.
•
rev. 2.0
Relay
Actions to do
Alarm Relay Close
- Push Enter Key to open
Alarm Relay
- Restore Product tank
Alarm Relay open
- Push Enter Key to reset
Alarm Relay Close
- Push Enter Key to reset
Alarm Relay open
- Restore Flow Rate
Alarm Relay Open
- Press Enter Key to replace
Default parameter
- Destroy Unit
Alarm Relay open
- Restore Probe or Buffer
solution and repeat calibration
function
Init.default__no
Init.default__Yes