To de-activate rapid thaw:
Proceed as above, but select off for normal operation.
Defrosting
Defrosting is automatically performed 4 times every 24 hours. If the cabinet is operating
under severe load (frequent door opening and frequent replenishment) manual
defrosting can become necessary. The cabinet can be manually defrosted by switching it
off and on. It will then start to defrost. The next defrost will occur 6 hours later.
up to indicate a defrosting cycle.
Do not use sharp or pointed objects to
accelerate the defrosting process.
The number of daily defrosts can be changed as follows:
• Press
P + 1
• Press
+
until dEF is shown on the display.
• Press
P
to display the current setting.
• Press
+
or
• Once the required value has been selected, press
• Press
twice to exit the menu.
Power failure
In the event of a power failure, the control remembers the temperature setting and
restarts the cabinet when power is restored. If the power failure persists for some time,
the control might revert to the factory setting.
Cleaning
Always disconnect the cabinet before cleaning.
Do not flush compressor compartment and evaporator with water as this may cause
short-circuits in the electrical system.
The cabinet should be cleaned internally with a mild soap solution at suitable intervals
and checked thoroughly before it is put into operation again.
For the external maintenance – use stainless steel polish.
76-504-1245
for more than 3 seconds.
-
to change the setting.
P
to confirm the new setting.
lights
23