Parameter "P-11"
Hysterersis
Select parameter "P-11" , available setting range is :
0.5-2°C, factory default value is 0,5°C.
Note:
This hysterersis is only valid when the parameter
"P-06" is set as "Room Sensor" or "Floor Sensor".
Parameter "P-12"
Over Current Alarm
Select parameter "P-12", "AL"
means alarm set, available
setting range is:
AL.y: Over current alarm is
enabled,
AL.n: Over current alarm is
disabled.
When the load is over 16.4A,
the display will show "Warm"
and "Cu" , the beeper will
sound, the relay will be forced
to turn off, the device will
report every 1 minute until the
Alarm Interface
alarm is cancelled.
Press and hold button
for over 5 seconds to
cancel the alarm.
Parameter "P-13"
Button Vibration Level
Select parameter "P-13", "vI"
means vibration,
available setting range is:
vi.0: vibration disabled (factory default),
vi.1: Low,
vi.2: Mid,
vi.3: High
Parameter "P-14"
Open Window Detection
Select parameter "P-14",
available setting range is:
0 & 1~10, unit is °C, 0 means
this function is disabled,
factory default value is 5.
Once the device is powered on and operating in a
stable environment, if the room sensor temperature
decreases by the threshold value above within 10
minutes, the icon
will flash slowly, and the device
will activate frost protection mode, the default frost
protection temperature is 5°C.
After open window detection
is enabled, if the room sensor
temperature increases by 2°C
within 10 minutes, or if the
power to the device is reset,
or operation mode is changed
Window Open
using APP, or operation mode
Detected
is changed using the device,
then the
icon will
disappear.
IMPORTANT:
Open window detection will always use the
internal room sensor of this device as reference
sensor to compare and detect.
Parameter "P-15"
Set The Time
Select parameter "P-15", and
enter "ti".
The time is displayed in the upper right hand corner,
the first two digits refer to the hour, the last two
refer to the minutes, press button
or
to
modify the hour or minute value, press
button
to switch between hour and minute settings and to
save the time.
Parameter "P-16"
Set The Day
Select parameter "P-16", and
enter "we".
Press button
or
to modify the day, available
setting range is Monday ~ Sunday. Press
button
to save the setting.
Parameter "P-17"
Select parameter "P-17":
- se.L: Local sensor, the device
will get room temperature from
its internal room temp sensor
(factory default),
- se.r: 1, DO NOT USE.
Parameter "P-18"
Home Screen Temperature Display
Select parameter "P-18", and
enter "tE".
This parameter is used to change the temperature
display shown on the home screen between
set temperature, room temperature or floor
temperature, available setting range is:
te.s: set point temperature,
te.r: room temperature (factory default),
te.f: floor temperature,
If the set point temperature is modified manually,
the display will show the temperature for 10S, then
display temperature according to the parameter
setting.
5