FUNCTION DESCRIPTION - ALARM -
When triggering the alarm, a difference is generally made between the two trigger types
"person and technical alarm".
PERSON ALARM:
Trigger:
- Is activated when one of the emergency buttons SW1...SW6 is pushed
Signal:
- The integrated LED signal lamp lights up for 2 seconds
alternating with the
- acoustic signal encoder / interval duration 10 seconds
- The signal lamp "Ready" goes out
- The display shows the number of the pushed emergency button
(button 1= „S1" / button 2 = „S2" / button 3= „S3" / button 4= „S4"
button 5= „S5" or button 6 „S6")
Note: The assignment of the emergency buttons can be programmed!
Confirmation:
- After unlocking the emergency button, the alarm can be reset by the button "Reset".
Attention:
Please note that when the RESET button is pressed for longer than 10s, a restart is carried out!
Afterwards, the unit is in the delivery state and must be set again.