Pull the safety bond through the attachment eyelet and over the trussing system or a safe fixation spot.
Insert the end in the quick link and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!

DMX-512 connection / connection between fixtures

The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Only use a DMX-cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
Connection between devices
The device is equipped with a lockable power input connector. Afix the power cord and turn it to the right
until it locks. Plug the power cord into a grounded electrical outlet that matches the rated voltage of the
machine.
On the rear panel, there is a lockable mounted socket (Power Out). Connect the output with the mains input
of the next fixture until all fixtures are connected.
Please note: A maximum of 8 devices may be linked together. After every 8 devices, the fixtures must have
a renewed connection with the power mains.

Master/Slave-Operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the LED PFE-100 RGBW Profile Spot you can find an XLR-jack (DMX Out) and an XLR-
plug (DMX In), which can be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT jack with the DMX IN plug of the next device.
Please see further instructions under Operation.