Rectifying malfunctions

Rectifying total failure

DANGER
Fatal electric shock due to coming into
contact with live components.
Do not carry out any repairs on the
device.
Never open the device.
If the device is defective, contact the
superrollo customer service.
The cause of a total failure is usually a defective motor.
A defective motor may be attributable to the following
causes:
■ The motor has been severely overloaded due to a
fault in the mechanical system.
■ The roller shutter has been blocked due to icing,
resulting in motor overload.
If your device's motor is defective, the device must be
dismantled and repaired by the superrollo customer
service. Proceed as follows to do this:
Remove the mains cable plus from the mains
socket.
Relieve the roller shutter by supporting it using a
suitable object or with a second person.
Open the winding compartment cover.
Press into the opening of the gear release (1) using
a thin pin and keep pressing.
Pull the belt upwards out of the device as far as
possible.
Release the belt from the fastening hook.
Pull the belt completely out of the device.
Close the winding compartment cover.
Dismantle the device in accordance with the
instructions in the section entitled Dismantling the
device from page 62.
Have the device checked by the superrollo customer
service.