Commission the new Access
system
Procedure
1 Establish an active connection to
the Access server using the commis-
sioning computer.
2 Start the Firefox browser on the
commissioning computer.
3 Enter the individually assigned
IP address of the server operating
system.
4 The login screen of the Access
server is accessed and opens in the
browser window.
5 Log into the Access server
(Account name: admin / Password:
admin).
Note
When first logging in to the Access
system, the page Siedle Access
Licensing Agreements is displayed
once.
6 Read all licensing agreements
through carefully and save them
locally in your management struc-
ture.
7 Click on Done when you have
read and accepted the licensing
agreements.
8 You are now on the start page
(Dashboard) of the Access server.
Restore the existing configuration
Procedure
1 In the navigation area, click on the
System maintenance menu.
2 The System maintenance menu
opens up.
3 In the navigation area, click into
the opened System maintenance
menu on System backup.
4 The System backup page opens
up in the content area.
5 In the area Import/export
system backup, select the option
Upload backup:.
6 Click on Browse.
7 Navigate in your Windows
Explorer to the storage location of
the backup file.
8 Click on Restore.
9 Read the notes contained in the
confirmation prompt and confirm
with Yes, if you wish to continue
with the backup.
10 The backup is imported. The pro-
cess can take some minutes.
11 Successful completion of the
system restoration is confirmed with
a message.
Check and save basic parameters
Procedure
1 Open the menu System main-
tenance > Basic parameters.
2 The Basic parameters menu
opens with the index tab Notices.
3 Change to the index tab Server.
4 Document the hardware ID gen-
erated by the Access Server (e.g.
AAAA-BBBB-CCCC-DDDD-EEEE)
in this document to allow this to
be used for requesting the new
licences.
5 Enter the IP address of the Access
system assigned in the server
operating system, and change
the already entered IP address to
the required IP address. The IP
addresses must agree with the
address in the server operating
system. Otherwise the terminals
cannot connect to the Access server
and the Access system would not
work correctly.
6 Click on Save to take the changes
over in the system.
7 With the save routine, the server
services are restarted.
Using this process, terminals are
given the latest firmware.
23