MB 3000 G
min.
3 cm
Two spacers are included with the MB3000G. These must be attached to the rear of the unit as shown in
the figure, before positioning the unit against the wall.
Do not locate the unit below a ceiling fan or right next to air-conditioning equipment.
To ensure proper function, the device must be standing horizontally. Use a water level to check and to cor-
rect if necessary.
The MB3000G is equipped with 4 bearing rolls.
Once it is in its final position, the feet must be
unscrewed to immobilise it and stop it rolling away.
Screw the feet with the provided key until the rolls
do not touch the floor anymore.
Make sure that during operation the drainage plug is
closed properly.
CLEANING / DISINFECTING
Clean or disinfect the unit inside and outside before using it. Use only gentle cleaning agents. Never use
aggressive or caustic cleaning agents, scouring powder, steel wool, abrasive sponges or chemical solvents.
When cleaning, make sure that no fluids of any kind run into the ventilation housing.
For disinfecting, we recommend all the surface disinfecting agents commonly used by the customer,
provided they are recommended by the German Association for Hygiene and Microbiology (DGHM) or other
national organisations. For disinfecting small areas, we recommend using a concentrated alcoholic agent.
POWER SUPPLY / ELECTRICAL CONNECTION
Before connecting the unit, check whether the details on the nameplate on the back of the unit correspond
to local values.
Before connecting the MB3000G and switching it on for the first time, allow it to stand for 30 minutes.
To prevent problems with other electrical equipment causing this unit to malfunction, it should be con-
nected to a separate circuit. Never connect the unit to a single socket with other electrical equipment by
means of a multi-socket.
Make sure that the plug of the unit is easily accessible so that if need be it can be easily disconnected without
having to move other equipment or furniture.
The MB3000G is equipped with a compressor which requires low starting current and can also operate
within a range of voltage variations. E.g. if the normal operating voltage is 230 volts, 50 Hz., A.C., it can work
even when the supply voltage occasionally go as low as 115 volts or as high as 254 volts.
Though the MB3000G is capable of operating within a wide range of voltage variations, for extra safety one
separate Automatic Voltage Stabilizer should be used with it.
min.
10 cm
5