DIAGNOSTIC CODE
Up Arrow Down Arrow
Flash(es)
Flash(es)
5
1
Terminal 1+2 for wall control is short-
ened longer than 4 seconds
5
5
Low voltage
6
1
Maximum radio memory has been
reached.
34
Optional Accessories
Always use Chamberlain accessories. External products can cause malfunctions.
1. TX4RUNI -
4-channel remote control
2. 128REV -
Wireless Wall Control 2-Channel
3. 747REV -
Keypad
4. 830REV -
myQ Starter Kit (Gateway + Photocells)
5. 829REV -
Garage Door Monitor
6. 1REV -
Quick release
7. 1702REV -
Quick release
8. 75REV -
Wired push button
9. FLA-1LED -
Flashing light
10. 771REV -
Photocells
11. 41REV -
Key switch (surface mount)
12. 16200LM -
Door in Door contact
SYMPTOM
Check wiring for push button if button is stuck and activated permanently. Remove
wiring from terminal 1+2 on operator as test. Do not run push button wires next to high
voltage wiring or in same conduit.
The operator has been shut off due to lower voltage supplied than allowed.
If mains supply is used, check wiring and supply.
Maximum capacity for storage of remote controls has been reached. The first remote
control or more previously programmed remote controls' codes have been replaced by
a new one. To reset diagnostic remove power from the operator.
SOLUTION