Herunterladen Diese Seite drucken

tau K690M Bedienungs- Und Wartungsanleitung Seite 13

Werbung

1_
INSTALLATION WARNINGS
GENERAL SAFETY REQUIREMENTS
1)
Carefully read all instructions before installation, as they
provide important instructions regarding the safety, in-
stallation, operation and maintenance. Incorrect instal-
lation or use of the product may lead to serious physical
injury.
2)
Never leave packaging materials (plastic, polystyrene etc.)
within the reach of children as they constitute a potential haz-
ard.
3)
Keep the instructions in a safe place for future consultation.
4)
This product has been designed and constructed exclusively
for the use specified in this documentation. Any other use not
specified herein may impair product integrity and/or consti-
tute a hazard.
5)
TAU declines all liability for improper use or use other than as
specified for this automation.
6)
Never install the product in explosive atmospheres.
7)
The mechanical elements must comply with the requirements
as stated in the standards EN 12604 and EN 12605. For non
European member states, in addition to the national refer-
ence standards, the above-mentioned standards must be ob-
served to ensure an adequate level of safety.
8)
TAU is not responsible for failure to observe Good Practice
in construction of the doors to be power-operated, nor any
deformations occurring during use.
9)
To ensure the maximum safety, in consideration of the haz-
ards that may arise during installation and use of T-SKY, the
installation procedures must be performed in full compliance
with the law, current standards and regulations. This chapter
contains general warnings, while other important warnings
are provided in chapters "Preliminary Checks" and "Commis-
sioning".
According to the most recent legislation, the installa-
tion of a power-operated door or gate must be in full
observance of the standards envisaged by European
Directive 98/37/EC (Machinery Directive) and in particu-
lar the standards: EN 12445; EN 12453 and EN 12635,
which enable the declaration of presumed conformity.
10) Before installation, an assessment of the associated risks
must be made, including a list of the essential safety require-
ments as envisaged in Appendix I of the Machinery Directive,
specifying the relative solutions adopted. Note that the risk
assessment is one of the documents included in the automa-
tion Technical documentation.
11) Check whether other devices are needed to complete the au-
tomation with T-SKY on the basis of the specific conditions
of use and dangers present; take into account all risks of im-
pact, crushing, shearing, dragging etc. and other hazards in
general.
12) Installation must comply with all provisions of Standards EN
12453 and EN 12445. In non-EU member states, as well as
national reference standards, the afore-mentioned standards
should also be observed to guarantee an adequate level of
safety.
13) Before performing any operations on the system, disconnect
from the mains and detach the batteries.
14) On the automation power line, install a device for disconnec-
tion from the power mains with a gap between contacts equal
to or greater than 3 mm. Use of a 6A thermal magnetic circuit
breaker with multi-pole switch is recommended.
15) Check upline of the system that there is a residual current
circuit breaker with a threshold of 0.03 A.
16) Ensure that the earthing system is to professional standards
and connected to the metal section of the door.
17) The safety devices (standard EN 12978) enable the protec-
tion of danger areas from risks associated with mechani-
cal movements such as crushing, dragging and shearing.
18) The use of at least one luminous indicator is recommended
for each system, as well as a warning notice fixed suitably
to the frame structure, in addition to the devices specified in
point 18.
19) TAU declines all liability for the safety and efficient operation
of the automation in the event of using system components
not produced by TAU.
20) For maintenance, use exclusively original TAU parts.
21) Never modify components that are part of the automation
system.
22) The automation may only be used after completing the com-
missioning procedure as specified in chapter 5 "Testing and
commissioning".
23) The installer must provide all information regarding manual
operation of the system in the event of an emergency and
supply the system User with the "User Guide" enclosed with
the product.
24) Never allow children or other persons to stay in the vicinity of
the product during operation.
25) Keep all radio controls or other pulse supplier device out of
the reach of children to prevent inadvertent activation of the
automation.
26) Transit below the door must occur exclusively when the auto-
mation is stationary.
27) The user must never attempt to repair or intervene directly
on the product; always contact qualified personnel for assist-
ance.
28) Before accessing internal terminals under the T-SKY cover,
disconnect all power circuits. If the disconnect device is not in
a visible location, affix a notice stating: "CAUTION: MAINTE-
NANCE IN PROGRESS".
29) Maintenance: at least every six months, make a general
check of the system, with special reference to the efficiency
of the safety devices (including, when envisaged, the opera-
tor thrust force) and release mechanisms.
30) All actions not expressly envisaged in these instructions
are strictly prohibited.
All documentation related to the system should be kept inside
or in the immediate vicinity of the control unit.
2_
PRODUCT DESCRIPTION AND INTENDED USE
(fig. 1)
T-SKY is a range of gearmotors destined for the automation of sec-
tional doors and, by means of the special accessory P-100BANT
not supplied, spring or counterweight up-and-over doors, project-
ing and non-projecting.
2 solutions of T-SKY are available: one with a single track sliding
guide (L= 3m – moving parts are already assembled at the factory)
or in the 3-section version for assembly (moving parts need to be
assembled by the installer).
The irreversible system guarantees mechanical blocking of the
door when the motor is not operating, and therefore no lock is nec-
essary; an internal and external manual release (optional) enable
door manoeuvres in the event of a power failure or when out of
service.
The buffer battery accessory P-200BATTSKY (optional) is also
available, which enables certain manoeuvres in the event of a
mains power failure.
The T-SKY automation has been designed and con-
structed for indoor use and to control vehicle access.
Any other use is strictly prohibited.
1_
Base
2_
Cover
3_
Door
4_
Control unit
5_
Courtesy light
6_
Gear unit
7_
Sliding guide
8_
Drive carriage
9_
Door attachment bracket
10_ Front attachment
11_ Chain tensioner
12_ Rear attachment
13_ Release knob
T-SKY Series
13

Werbung

loading

Diese Anleitung auch für:

T-sky