7.2 Maintenance
Regular inspection and servicing have a positive effect on the reliable
functioning of the product and should be carried out at least once a year.
Except for the necessary filter replacements, the product operates
maintenance-free.
Observe the warning notices for servicing and troubleshooting in the
"Safety" chapter.
7.2.1 Changing the filter – Safety instructions
The life of the filter inserts depends on the type and amount of deposited
particles.
As the dust accumulation in the filter increases, its flow resistance
increases and the extraction capacity of the product decreases.
Even with products that may have automatic filter cleaning, adhering
deposits can reduce the extraction capacity.
A filter change is required.
WARNING
Health hazards caused by welding fume particles
Do not inhale welding dust / smoke! Serious injury to the lungs and
respiratory tract is possible!
Sweat smoke contains substances that can cause cancer!
Skin contact with welding fume particles can cause skin irritation in
sensitive individuals.
To avoid contact with and inhalation of these dust particles, wear
disposable overalls, protective goggles, gloves and a suitable Class FFP2
respiratory protection filter mask in accordance with EN 149.
WARNING
Cleaning the filter inserts is not permitted. This inevitably leads to
damage to the filter element, meaning the filter ceases to function and
hazardous substances enter the air.
During the work described in the following section, pay particular
attention to the seal on the main filter. Only an undamaged seal allows
the product to achieve a high filter efficiency. Main filters with a damaged
seal must therefore be replaced every time.