UPDATING SETTINGS ACCORDING TO TYPES OF
1 - ACCESS THE SETTINGS VIA THE QAA 73 ROOM SENSOR
Do not change the settings of the LMU
!
when the burner is in operation (othe-
rwise the QAA73 must be disconnected
and then reconnected).
When switched on:
- The name of the manufacturer and the version of
the QAA73 scroll on the display..
- The time and day is set using the line selection
and OK buttons..
1.1 - Setting of the room sensor
Room unit configuration and parameter settings of
the room sensor to be made by the heating engi-
neer.
Buttons
1
2
3
6 720 812 420 (2015/11)
QAA73.210
INSTALLATION
Press the Info button for at least 3 secondes
- This will take you to the programming mode "End-user". (1. level)
- The "HEURE" menu is displayed.
Display :
HEURE
Press another time the Info button for at least 3 secondes
- This will take you to the "user" level
- The "UtiL" level is displayed.
Display :
Util
By pressing the line selection button, choose the required operating level.
(UtiL = End-user/ INSt = Heating engineer / OEM = OEM)
Press the OK button to confirm your choice
- 1 -
- CHRG appears on the display or after a pro-
longed period out of service.
During this time, it is not possible to display or
change parameters but the other functions are
usable. After a few minutes, a minimal power re-
serve is reached and all functions are available.
To change the setting value, this value
!
should be flashing on the display.
Explanation
QAA73.210