※The outlet through which the pipings are
taken out is available in three directions.
※Pipes can be taken out in 3 directions(rear, right
or top).(See fig.3.3.3)
Cut out holes using nippers, etc.
Cut out holes to taken out pipes along the cutoff line
on the rear cover.
Cut out the top face cover aligning to the piping
position.
When taking pipe out to right-hand side, cut out a
hole along the groove at the inside of the side
panel.
After installing pipes and wires,seal clearances
around pipes and wires with putty,etc. to shut off
dust.
Make sure to install the covers at rear and top in
order to protect the inside of unit from intrusion of
dust or protect wires from damages by sharp edges.
When taking them out to the right-hand side,
remove burrs or sharp edges from the cutout.
Top outlet
Right outlet
Drain outlet
(right)
3.3.3Indoor unit preparation
(1)Remove the air return grille.
Slide stoppers (4 places) of the catches, then
remove the screws(4 or 6 places).
Screw
UNIT:mm
Rear outlet
Drain outlet
(rear right)
Fig. 3.3.3
Fig. 3.3.4
(2)Remove side panel.
Remove the screw and detach the side panel by
sliding it toward the direction indicated by the
arrow mark.
(3) Remove the hanging plate.
Remove the screw and then fixing bolts.
Drain outlet
(left)
Hanging plate
screw (M5)
Drain outlet
(rear left)
Hanging plate
Hanging plate
fixing bolts(M8)
3.3.4Install the indoor unit
Ceiling type installation
(1)Select the suspension bolt locations and the pipe
hole location.
i
.Use enclosed paper pattern as a reference, and drill
Screw
the holes for the suspension bolts and pipe.
Note:Decide the locations based on the direct
measurements.
ii.Once the locations are properly placed, the paper
pattern can be removed.
2)Install the suspension bolts in place.
12
Installation and Maintenance
Side panel screw
(1 each on the left and right)(M4)
Side panel
Fig. 3.3.5
Fig. 3.3.6 Suspension bolts and nuts
Ceiling
Pattern board
Walls
Fig. 3.3.7