Herunterladen Diese Seite drucken

Bosch 3 601 K81 3 Originalbetriebsanleitung Seite 77

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
24 | English
Do not expose the measuring tool to any extreme temperatures or variations in
u
temperature. In case of large variations in temperature, leave the measuring tool
to adjust to the ambient temperature before switching it on. The accuracy of the
measuring tool and the functionality of the display may be compromised if exposed to
extreme temperatures or variations in temperature.
Avoid hard knocks to the measuring tool or dropping it. After severe external influ-
u
ences and in the event of abnormalities in the functionality, you should have the
measuring tool checked by an authorised Bosch after-sales service agent.
Certain ambient conditions fundamentally impair the measuring results. These
u
include, e.g. the proximity of devices that generate strong electric, magnetic or
electromagnetic fields, moisture, metal building materials, foil-laminated insula-
tion materials or conductive wallpaper or tiles. Therefore, also refer to other in-
formation sources (e.g. construction plans) before drilling, sawing or routing into
walls, ceilings or floors.
Hold the measuring tool by the intended gripping surface (8) only, so as not to
u
influence the measurement.
Do not attach any stickers or labels to the sensor area (13) on the rear of the
u
measuring tool. Metal labels in particular will affect measuring results.
Do not wear gloves when taking measurements and make sure that you
are properly earthed. If you are not properly earthed, the identification of live
wires may be impaired.
When taking measurements, avoid devices that emit strong electric, mag-
netic or electromagnetic fields. If possible, deactivate all tools whose radi-
ation could interfere with the measurement and switch off the corresponding
functions or tools.
Starting Operation
Switching on/off
Before switching on the measuring tool, ensure that the sensor area (13) is dry.
u
If necessary, use a cloth to dry the measuring tool.
If the measuring tool has been exposed to a significant change in temperature,
u
leave it to adjust to the ambient temperature before switching it on.
To switch on the measuring tool, press the on/off button (5).
To switch off the measuring tool, press the on/off button (5) again.
If no button on the measuring tool is pressed for approx. 5 mins, and no objects are de-
tected, the measuring tool will automatically switch itself off to preserve battery life.
1 609 92A 7ZF | (21.06.2022)
Bosch Power Tools

Werbung

loading

Diese Anleitung auch für:

D-tect 120 professional