22 | English
(i) Measuring indicator
(j) Fine scale
(k) Object centre indicator CENTER
Technical data
Digital Detector
Article number
A)
Max. detection depth
– Ferrous metals
– Non-ferrous metals (copper)
– Live wires 110−230 V (with voltage applied)
– Wood
Operating temperature
Storage temperature
Inductive sensor
– Operating frequency range
– Max. magnetic field strength (at 10 m)
Capacitive sensor
– Operating frequency range
– Max. electric field strength (at 10 m)
Max. altitude
Relative air humidity max.
Pollution degree according to IEC 61010-1
Battery
Approx. operating time
Weight according to EPTA-Procedure 01:2014
1 609 92A 7ZF | (21.06.2022)
B)
–10 °C to +50 °C
–20 °C to +70 °C
Bosch Power Tools
GMS 120
3 601 K81 0..
120 mm
80 mm
50 mm
38 mm
5 ± 0.2 kHz
72 dBµA/m
20 ± 1 kHz
24 dBµV/m
2000 m
90 %
C)
2
1 × 9 V 6LR61
5 h
0.27 kg