Herunterladen Diese Seite drucken

GYS PROTIG 200 DC HF Bersetzung Der Originalbetriebsanleitung Seite 18

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
Translation of the original instructions
• Tack weld feature SPOT
SELECT STRIKING MODE
HF TIG: High Frequency start without contact
TIG LIFT : Contact start (for environments sensitive to HF disturbances).
Touch
Switch
Pré Gaz 0.5s
COMPATIBLE TORCHES
L
TORCHES AND TRIGGER MODES
DB
For the 1 button torch, the button is called «main button».
For the 2 buttons torch, the first button is called «main button» and the second button is called «secondary button».
P
2T MODE
t
t
Main button
Main button
T1
T1
4T MODE
t
t
Main button
Main button
T1
T2
T1
T2
18
PROTIG 200 DC HF
A
TIG SPOT
The grey areas are not useful for this mode.
Lift
1- Touch the work-piece with the electrode
2- Press the trigger on the torch
3- Pull back the torch to lift the electrode.
<1s
L
DB
P
t
t
T2
T2
t
t
T4
T3
T4
T3
I N V E R T E R
W E L D E R
JOB
A
T1 - The main button is pressed, the welding cycle starts (PreGas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped
(DownSlope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the secondary but-
ton works like the main button.
T1 - The main button is pressed, the cycle starts at PreGas and stops in
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
T3 - The main button is pressed, the cycle switches to DownSlope and
stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
Nb : for torches, double button and double button with potentiometer
=> command « up/welding current » and active potentiometer,
command «low » inactive.
EN

Werbung

loading