Herunterladen Diese Seite drucken

EuroLite Mirror Ball 30 cm + Motor MD-1515 Bedienungsanleitung Seite 15

Vorschau ausblenden Andere Handbücher für Mirror Ball 30 cm + Motor MD-1515:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

the motor must be taken out of operation immediately and the mirrorball must be uninstalled. The whole
installation has to be checked for defects by an expert.
Make sure that the rotation of the mirrorball is never slowed down or stopped by decoration material etc.
Make sure that no side forces can impact on the installation.
Make sure that the mirrorball cannot be moved by air streams. The mirrorball and the motor must be installed
and operated absolutely swivel free.
Please check in regular intervals, if the installation material (e. g. key ring, shackles or screw-on chain links)
or chain links have been deformed. Uninstall the mirrorball immediately in such a case.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Before taking into operation for the first time, the installation has to be approved by an expert!
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Maintenance and service operations are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
International
L
N
DANGER TO LIFE!
15/29
00026908.DOC, Version 2.0

Werbung

loading