7 Divers
7.1 Corresponding value for sensors (NTC 10K)
To be check with an Ohmmeter, only when the sensor is
disconnected
0°C / 32°F
5°C / 41°F
10°C / 50°F
15°C / 59°F
20°C / 68°F
25°C / 77°F
30°C / 86°F
35°C / 95°F
40°C / 104°F
7.2 Memory safe
- All volatile memories (Hours, Date) are saved in case of power
supply lost during 4 hours. To have a maximum time save your
product must be plug-in during minimum 1 day.
- All others parameters (installation, program...) are saved all the
time (infinite memory save)
~32 KΩ
~25 KΩ
~19,7 KΩ
~15,6 KΩ
~12,5 KΩ
~10 KΩ
~8,1 KΩ
~6,5 KΩ
~5,4 KΩ