Herunterladen Diese Seite drucken

TFA 30.1052.02 Bedienungsanleitung Seite 16

Digitales profi-thermometer mit kabelfühler

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
TFA_No. 30.1052_Anleitung
Digital professional thermometer with cable probe
Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries
from the device and dispose of them separately.
This product is labelled in accordance with the EU Waste Electrical and
Electronic Equipment Directive (WEEE).
This product must not be disposed of in ordinary household waste. As
a consumer, you are required to take end-of-life devices to a designated
collection point for the disposal of electrical and electronic equipment,
in order to ensure environmentally-compatible disposal. The return
service is free of charge. Observe the current regulations in place!
Disposal of the batteries
Never dispose of empty batteries and rechargeable batteries with ordinary
household waste. They contain pollutants which, if improperly disposed
of, can harm the environment and human health.
09.10.2023
12:30 Uhr
Seite 16
– 30 –
Digital professional thermometer with cable probe
As a consumer, you are required by law to take them to your retail store or
to an appropriate collection site depending on national or local regulations
in order to protect the environment. The return service is free of charge.
The symbols for the contained heavy metals are:
Cd=cadmium, Hg=mercury, Pb=lead.
11. Specifications
Measuring range - temperature
-40°C (-40°F) ...70°C (158°F)
Temperature accuracy
± 0.3 °C (-10...+20°C),
± 0.5 °C (-20...-10°C , +20...+40°C),
± 1 °C (-40...-20°C, +40...+70°C)
Measuring interval
Every 10 seconds
Power consumption
2 x 1,5 V AAA batteries (not included)
– 31 –