1. Close ball valve in the output, connect a hose to the drain valve and route
into the supplied collecti on bag. Use water at mains pressure to rinse out
the resin, let the water drip out and dispose of resin with the household
waste.
2. Unscrew the reinforced hoses, unscrew the head unit.
3. Fill in new resin, re-att ach the head unit, clean the thread with some
water to remove any resin and moisten the newly added resin at the
same ti me. This makes centring the brass head much easier. Connect the
reinforced hoses, reset the combined meter to "0" (see chapter 5.2.)
6.2. Changing the batt eries on the combined meter
When the batt ery symbol (
the 4 screws on the red cover, lift off the cover and replace the three 1.5 Volt
AAA (LR03) batt eries with new ones. Make sure the cover seal is seated
properly. Replace the cover and secure with the screws. Check the device is
working correctly.
For detailed informati on about the combined meter, see the
PUROTAP® LFM-20 product page on our website.