 After having made the connections and opened the pressure regulator at the lowest
pressure (0,5MPa), regulate the correct pressure value (~ 0,02 – 0,05 MPa) for welding by
means of the valve situated on the hose with gauge.
 Close the valve on the bottle or disconnect the 950 cc cartridge after having completed the
operations and go on with disconnection.
3.
Checking the correct calibration of pressure gauges and pressure switches
The kit being equipped with a pressure gauge with scale – 0,1 + 5,3 Mpa, class 1, it is possible
to check the correct calibration of pressure gauges (4) and pressure switches by connecting
them to the ends of the hose with pressure gauge.
2.5

Storage

The pressure regulator must be stored as a precision instrument. It must be stored in its
case so that to be protected from accidental shocks or from dust, oil, or any other impurity.
3

Care and Maintenance

Replacement parts are available on request. If you notice something wrong in the
regulator, which cannot be repaired following these instructions, send it back to
your distributor.
Do not clean the gauges glasses with petrol, solvents or detergents of any type.
Malfunctionings
-
In case of malfunctioning (for ex. leaks from the gauges or from the safety valve), stop
using the pressure regulator and immediately close the bottle valve.
-
If no damage can be seen on the outside of the regulator, we suggest to send it back to
your distributor, so that it can be checked and repaired.
Do not use the pressure regulator if there are the following malfunctionings
-
The seal gaskets used for the connection to the bottle are damaged or missing.
-
The regulator or some of its parts (gauge, input or output connection) are damaged or
contaminated by dirt.
-
Joints are leaking.
-
The safety valve regulation has been modified or gas is coming out of the valve.
Safety valve
For safety reasons, the pressure regulator is equipped with an overpressure valve.
In case of functioning defects, this valve lets the excess gas pressure flow towards the outside.
It is absolutely forbidden to modify the safety valve calibration!
Tightness check
-
To check the pressure regulator tightness, operate in the open air with soapy water or with
special detectors.
-
Spray the detector on the area that must be checked.
-
The detection of gas leaks is enhanced by the forming of bubbles or foam.
4

Customer service

The ROTHENBERGER service locations are available to help you (see listing in catalog or on-
line) and replacement parts and service are also available through these same service locations.
Order your accessories and spare parts from your specialist retailer or using RO SERVICE+
online: ℡ + 49 (0) 61 95/ 800 8200
www.rothenberger.com
5

Accessories

You can find suitable accessories in the main catalog or at www.rothenberger.com