Where to locate the fan
Locate it as high as possible. At least 110mm
!
from the edges of the mounting surface to
the centre of the hole. As far away as possible
from and opposite to the main source of air
replacement to ensure airflow across the
room (e.g. opposite the internal doorway).
Near the source of steam or odours.
Not where ambient temperatures are likely
!
to exceed 50°C. If installed in a kitchen,
fans must not be mounted immediately
above a cooker hob, or eye level grill.
If installing in a room containing a fuel
burning device which has a non-balanced
What you will need
Always check the appropriate size of
A
space before installing the fan.
Wall Mounting
B
Ceiling Mounting
C
flue, it is the installer's responsibility to
ensure that there is enough replacement air
to prevent fumes being drawn down the flue
when the fan is operating up to maximum
extract. Refer to Building Regulations for
specific requirements. Exhaust air must not
be discharged into a flue used for exhausting
of fumes from appliances supplied with
energy other than electric. Requirements of
all authorities concerned must be observed
for exhaust air discharge and intake flow
rates. Not suitable for use in possible
chemical corrosive atmospheres.
Australia Only
VX100 / VX120 / VX150
clearance between contacts.
Australia Only
VX100T / VX120T / VX150T
clearance between contacts.
UK only (all variants)
07