Herunterladen Diese Seite drucken

LEGRAND LEXIC 036 57 Bedienungsanleitung Seite 18

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
Use
• After a mains failure, the remote control dimmer returns to the
status it was in prior to the failure (status memory)
• After switching off, each time the product is switched on via a
short press on the controls the last lighting level is restored
(level memory)
In remote control dimmer mode
Adjust the min. lighting level using the setting button on the pro-
duct
- Via local control on the product, activate pushbuttons or per-
ipheral devices 744 23 - 841 37/87 (between A and B)
Short press = lighting level / off
Long press = minimum lighting level then increasing / decrea-
sing variation of lighting level (direction of variation reversed on
each press)
- Control via double pushbuttons 744 10 - 841 30/80
+
key : Short press = lighting level
Long press = increasing variation of lighting
--
key : Short press = off
Long press = decreasing variation of lighting
- Control via auxiliaries : 744 07/08/09 - 841 32/31/47/82/ 81/97
refer to individual instructions
T V E
In dimmer mode
Set the lighting to the required level using the setting button on
the product
- Via local control on the product, activate pushbuttons or per-
ipheral devices 744 23 - 841 37/87 (between A and B)
Short or long press = required lighting level / off
- Control via double pushbuttons 744 10 - 841 30/80 (between A,
C and D)
+
key : Short or long press = required lighting level
--
key : Short or long press = off
- Control via auxiliaries : 744 07/08/09 - 841 32/31/47/82/ 81/97
refer to individual instructions
T V E
34
Utilisation (suite)
T V E
In slave mode
The controls are inoperative, control is via the master remote
control dimmer
Recommendation : To achieve the same level of dimming at
each lighting point, use identical loads
35

Werbung

loading