Technical characteristics (continued)
• Protection via electronic device
- In the case of an overload, or above the maximum operating
temperature, the device automatically adjusts power by
reducing lighting (the indicator lamp turns orange)
- In the case of a short-circuit or very high overload,
the remote dimmer automatically switches off
(the indicator lamp turns red)
Once the fault has been corrected, the device is switched back
on by pressing the local control button for at least 3 seconds
(the indicator lamp turns green)
The product is then ready for use
• Own consumption : 9 W
• Storage temperature : –5°C to +65°C
• Operating temperature : –5°C to +35°C (derating above 35°C)
• Mounting on
rail
• Dimensions for 6 modules (108 mm)
• Capacity of connection terminals :
- 2 x 2,5 mm
2
rigid or flexible wire with cable end
- The L+N supply can be connected via Legrand supply bus-
bars, Cat. No. 04926
Each control pushbutton and auxiliary must be connected
using a wire with a cross-section of 1,5 mm
Construction conforming to the following standards :
NFC 61 111 / CEI 669-2-1 / EN 55022 / VDE 875
Important :
If the connection diagrams are not observed, the equipment
will be destroyed
Before any operation on the lighting circuit, open the ups-
tream protective device
2
28
Description
Illuminated indicator
Green = Switched on
Label
Orange = Overload
Red = Switched off
holder
Control terminals
E
F
A B C D
Legrand
N
L
N
Mains
Operating
supply
terminals
terminals
• Lighting adjustment
button (if operating
switch is in position V)
• Minimum lighting
adjustment button
(if operating switch
is in position T)
Power extension
terminals
G H
9
7
5
11
T
V
E
3
13
1
15
Local
control
Operating switch
T = remote dimmer
V = dimmer
E = slave
29