0
Locomotive only runs in digital operation.
1
Locomotive runs both in digital and conventional operation,
flying splice possible.
4 (3)
0
RailCom transmission disabled
1
RailCom transmission enabled
5 (4)
0
factory pre-set speed curve is used
1
User defined speed curve is used
6 (5)
0
Decoder uses basic address (from CV1)
1
Decoder uses extended address (from CV17 and CV18)
7-8(6-7)
Not used
30
Bit
Fault display
1 (0)
1
Light short-circuit
2 (1)
1
Overheating
3 (2)
1
Motor-/Track short-circuit
CV
Range of
Function mapping for function outputs:
values
In order to allocate a function of the digital system to a function
33
output, look for the section where the row of the desired function
–
meets the column of the desired function output. Enter the
47
number found in the respective CV. For the purpose of
clarification, ex-works settings are shown in bold print.
Function:
CV
33
0-255
F0 vorwärts
34
0-255
F0 rückwärts
Function output:
A
B
C
D
1
2
4
8
1
2
4
8
E
F
G
H
16
32
64
128
16
32
64
128
35
E
0
0
0
0
0 (dec)
0
0
0
Ex-works
setting
1
2