Herunterladen Diese Seite drucken

OSRAM e:cue SYMPL dmx Node Installationsanleitung Seite 21

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

patterns and allows to change their properties.
To access the web interface, open a common web browser on a connected
PC. Enter the SYMPL dmx Node's IP address into the address bar:
e.g. http://192.168.123.1.
Open the Test mode page by selecting "TestMode" on the left side of the
web interface of the SYMPL dmx Node:
Fade:
dimming up and
down, alternating
Click a button to choose a test pattern. Define the properties:
Property
Output
Channel Count
Block Size
Offset
Value
Step Time
Click "set" to run the test and to apply changes in the test settings.
Strobe:
Const:
fast flashing
constant lighting
Description
DMX/RDM ports to run the test on.
Total frame length.
Block size in which to step through the frame length
in channel count.
Start address of the first test loop (first channel = 1).
Luminance of the test output (0 - 255).
Delay between steps. Manual: Press the Identify
button to move the block. Define the first channel at
"Start Address".
- SYMPHOLIGHT v5.0 or higher needed-
Chase:
consecutive lighting
of blocks
21

Werbung

loading