Test mode
To access the web interface, open a common web browser on a connected
PC. Enter the device's IP address into the address bar:
e.g. http://192.168.123.1.
At Startup Setting and Offline Setting, the setting "send MARK" sends a
MARK (a logical one) on the bus: no data are sent to the fixtures and the
DMX port awaits further commands. With the setting "High Impedance",
the same behavior without sending a MARK is configured. It is
recommended to use "High Impedance" for backup systems only.
Running Startup Setting is indicated by flashing DMX/RDM status LEDs.
Please note that when you select an content image (snapshot) at these
settings, the framerate of the displayed image is reduced to 20 FPS.
6
Test mode
- SYMPHOLIGHT v5.0 or higher needed-
The SYMPL dmx Node provides a Test mode for the connected DMX
devices. The Test mode is designed for DMX luminaires. There are two
kinds: using the Identify button and using the web interface of the
SYMPL dmx Node.
Please note that the Test mode overwrites all other DMX output like running
shows, Startup Setting's or Offline Setting's output for the time of testing. A
running show, the Startup and the Offline output respectively are reverted to
after exiting the Test mode.
The Test mode is indicated by flickering DMX/RDM LED(s) and the blinking
Test / Error LED.
Test mode via Identify button
See section (C) on page 11 at "2.4 Identify button: Identification & Reset
& Testing".
Test mode via Web interface
The web interface of the SYMPL dmx Node provides four different test
20