5.
Click "Submit" to apply the settings.
The network configuration of the SYMPL dmx Node is completed.
i
The employment of a discrete network is recommended.
i
Note down all employed and, if applicable, reserved IP
addresses. Keep the information for future network
configurations.
i
You can change the login password to the
SYMPL dmx Node's configuration page and the device
name of the SYMPL dmx Node at "Settings" page. Do not
forget the new password.
5.4
Extended DMX/RDM settings
DMX/RDM settings are configured via SYMPHOLIGHT at the properties of
the SYMPL dmx Node in the Setup Tab. Is the Node not connected to
SYMPHOLIGHT, extended DMX/RDM settings take effect.
Over the web interface of the SYMPL dmx Node you can define the
extended DMX/RDM properties for:
•
the period of powering up until a show takes over (Startup Setting)
•
the time of no e:net connection (Offline Setting) - after prior
connection to a show
•
DMX and RDM Break time and Mark
•
DMX to RDM wait Switch time (RDM Packet Space).
These properties are only configurable when the device is not assigned to a
show. SYMPHOLIGHT must have had control once over the Node for the
settings to take effect.
Network configuration