Installation
4.1
Installation conditions
Installation position:
Horizontal spacing:
Minimum vertical rail grid spacing:
Recommended vertical rail grid spacing:
Installation location
4.2
Mounting process
The e:cue SYMPL Node is designed to mount onto a 35 mm DIN rail
(EN 60715) in a vertical position.
SYMPL Node on any flat vertical surface. Use a 3 to 3.5 mm screw for the
hanger hole.
For mechanical stability, mounting on a rail is recommended.
4.3
Ethernet connection
The pin-assignment of the Ethernet port corresponds to RJ45 standards.
You can use every common Ethernet component, like cable, splitters, and
switches. Connect the SYMPL dmx Node at the designated Ethernet
interface with a patch cable (RJ45, CAT5).
14
Terminals on top and bottom
No spacing necessary
115 mm (90 + 25 mm)
(excluding conduit)
160 mm (with 40 mm conduit)
Indoor
1. Clip the device to the rail from
top.
2. Gentle pressure is then
applied to the top front to snap it
in place. The SYMPL dmx Node
has been mounted successfully.
You can also mount the e:cue