To exit the bootloader mode, short press the Identify button again.
Press the Identify button until Status and Test / Error LEDs blink
alternating, then blink together. Releasing the button now resets the
device to its factory settings. The password and other settings are reset
to their default values. Please note that the Offline Content cannot be
reset. To employ a reset Startup behavior, a restart of the device is
required.
Keeping the button pressed further on, the device proceeds to
normal operation. No changes apply.
(C) Use the Identify button also to test the connected fixtures to ensure
their correct installation.
Access the Test mode of the SYMPL Node by double-pressing the
Identify button during operation. The Test / Error LED signals the Test
mode by blinking short-short-long repeatedly. The Test mode starts at
the first DMX port with blinking lights of all channels (test pattern 1).
Single-press the Identify button to switch between the following
Test patterns:
- Chasing lights at intervals of 96 channels (pattern 2).
- All channels at 100% (pattern 3).
- All channels off (pattern 4).
- Alternate between the individual DMX ports and the four test
patterns. After the individual test of the DMX/RDM port 8, all DMX/
RDM ports are tested simultaneously. Another short-press starts
the test patterns from the beginning.
Exit the Test mode any time by double-pressing the Identify button
again. The device proceeds to normal operation. The DMX/RDM LEDs
no longer flicker and the Test / Error LED is off.
(D) Short press the Identify button if an error occurs and you want to exit
the error mode. The device will switch back to normal activity if the cause of
error is eliminated. The Node might reboot.