4 ... 20 mA
(≥ F.S.O)
0 ... 10 V
CANopen®
Bootup message
Fault:
a)
Missing position magnet
b)
Position magnet in zero or damping zone
c)
Malfunction or failure of the magnetostrictive element
During the power-up delay
(see Technical data, page
defined as an unusable signal. The machine controller must take this into consid‐
eration in its processing. After the power-up delay, the linear encoder is ready for
operation. The output signal behaves as described in the event of a fault.
7
Transport and storage
7.1 Storage
Store the device under the following conditions:
•
Recommendation: Use original packaging.
•
Do not store outdoors.
Store in a dry area that is protected from dust.
•
•
To allow any residual dampness to evaporate, do not package in airtight
containers.
•
Do not expose to any aggressive substances.
•
Protect from sunlight.
•
Avoid mechanical shocks.
•
For storage periods of longer than 3 months, check the general condition of
all components and packaging on a regular basis.
8
Technical data
You can obtain the technical data (specification parameters, dimensional draw‐
ings, STEP files and information on suitable accessories as well as the current
operating instructions for the product at www.sick.com. To do so, enter the prod‐
uct part number in the search field (part number: see the entry in the "P/N" or
"Ident. no." field on the type label).
9
Conformities and certificates
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part
number in the search field (part number: see the entry in the "P/N" or "Ident. no."
field on the type label).
For use in NFPA79-applications only
Enclosure Type 1
8028139/1LXF/2023/12/01/de, en
Output signal
> 21 mA
> 10.8 V
Position value = 0xFFFFFFFF
and EMCY message
16), the output signal is
DAX® | SICK