Herunterladen Diese Seite drucken

Dik Geurts Ivar 8 Low RS Installationsvorschrift Seite 38

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9.2.2 Heat shield (optional)
Using a heat shield will allow you to place the appliance closer to the wall. This 'heat shield kit' consists of two
guard plates and is optionally available through your supplier.
It is only possible to place a heat shield if the flue gas discharge is connected at the top of the appliance.
Caution!
Proceed as follows:
Guard plate attached to the appliance:
Ø
Loosen the 4 pre-mounted bolts at the rear of the appliance by a few turns (see appendix 2, fig. 5).
Ø
Place the plate against the back of the appliance.
Ø
Tighten the 4 bolts.
Guard plate attached to the discharge pipe:
(only applicable in case of a single wall pipe)
Ø
Allow the guard plate to rest on the appliance at the rear of the flue duct.
Ø
Then press the plate against the flue duct.
Ø
Drill 4 holes (Ø 4 mm) and fix the plate using the supplied screws (see appendix 2, fig. 6).
9.3 Interior lining
9.3.1 Vermiculite
The fire's vermiculite plates are located on the bottom and against the rear and side walls of the appliance.
In the following situations the vermiculite plates must be taken out:
The bottom plates are removed first and the rear plates are removed last.
Make sure that the vermiculite plates are placed back in their original position! The back plate, for instance, must
!Caution
be placed with the small, not countersunk, holes towards the front.
9.3.2 Flame baffle plate
On delivery the flame baffle plate (see Appendix 2, fig. 7) is located in the top section of the appliance.
In case of maintenance to the appliance, the flame baffle plate has to be removed.
To do this proceed as follows:
Ø
Take hold of the flame baffle plate and push the right side upwards.
Ø
Slide the flame baffle plate over the ridge to the right.
Ø
Lower the left side of the flame baffle plate and remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
The stainless steel profile must be placed at the front with the screw heads on top (see Appendix 2, fig. 7).
!Caution
38
When disassembling the air slide valve (see section 9.2.1).
When replacing the vermiculite plates.
I N S T A L LA T I ON M A N U A L

Werbung

loading