IN S T A LLA TION M A NU A L
9. Appliance-specific information
The appliance-specific instructions as described in this section prevail over the instructions in the other
!CAUTION
sections! If in doubt follow the instructions in section 9 or contact your supplier.
The appliance-specific information as described in paragraphs 9.1 to 9.5 applies to all models described in
this manual. Supplementary installation instructions (per appliance) are described in paragraph 9.6.
9.1 Smoke control area United Kingdom
The Dik Geurts Ivar 8 Store
burning stove have been recommended as suitable for use in smoke control areas when burning wood logs.
EA
The Ivar 8 Store
and Low
primary air control beyond the 6.0cm open position.
Olaf
EA
wood burning stove must be fitted with a permanent stop to prevent closure of the primary air control
beyond the 5.3 cm open position.
Exemption details can be found at: https://smokecontrol.defra.gov.uk/appliances.php
A limiting screw is accordingly supplied with all appliances. This is supplied as a kit in the combustion chamber.
This screw is therefore only used in the smoke control areas in the United Kingdom. In other countries this screw
can be disposed of in the appropriate way.
With the installation of an appliance in the United Kingdom:
Ø
Install the screw as shown in Appendix 2, fig. 3. After fitting, the air slide valve cannot be slid further shut than
legally allowed.
If this screw is not fitted or is removed the appliance will no longer be legally allowed to burn the permitted fuels
in Smoke Control Areas.
9.2 Air slide valve and heat shield
9.2.1 Air slide valve
When installing and maintaining the appliance, please check the operation of the air slide valve (see Appendix 2,
fig. 4). It is possible that steel grit entered the air slide valve during transport. If the air slide valve does not move
smoothly it must be cleaned. For this purpose, the air slide valve must be disassembled. The suspended air slide
valve is spring-mounted using a bolt and a spring, which are located below the cover plate.
When mounting the air slide valve, please proceed as follows (see Appendix 2, fig. 4):
If an outside air connection has been mounted, it must first be removed, before the air slide valve can be mounted
Caution!
(for removing the outside air connection: see section 9.5).
Ø
Remove the vermiculite plates from the bottom (see section 9.3.1).
Ø
Then remove the little square plate located in a recess below the vermiculite bottom plates.
Ø
Loosen the allen screw using the socket head wrench.
As soon as the bolt has been loosened, the air slide valve will fall down. Make sure you catch the air slide valve!
Caution!
Ø
Check the air slide valve and clean it if necessary.
In order to replace the air slide valve, proceed as described for removal, only in reverse order.
EA
RS
EA
/ Ivar 8 Store
, Ivar 8 Low
/ Ivar 8 Low
EA
wood burning stove must be fitted with a permanent stop to prevent closure of the
RS
wood burning stove and Olaf
EA
wood
37