Connection of several battery modules
Noteonthemaximumnumberofbatteries
You can use up to 4 battery storage modules
in parallel connection,
as shown in the connection sketch below.
Refer to the previous sections for the respective connection
procedure and proceed as follows for parallel connection:
• For power connection of several battery modules,
use an extra terminal block to which all battery power cables
are connected in order to connect them to the inverter.
(1).
• For the communication connection, connect only the first battery
module to the inverter as described before and connect further
batteries to each other via the CAN ports (2).
Connecting the Device
1
Inverter
Clamp
2
43