Controls and Operational Features
CITOCUT 25i front command panel.
Commands descriptions:
A. Output Current Knob: Potentiometer used to set the
output current used during cutting.
Technical Specification section for more information
about the machine rated current range.
Air Purge:
The Output Current Knob completely
rotated counterclockwise enables the air purge
function.
A 5 minutes timeout stops the purge
function; this happens only if the Output Current
Knob remains in the purge mode for a long time.
B. Power ON/OFF green LED: It lights up when the
machine is ON.
C. Output red LED:
See meanings in the following
table.
D. Thermal yellow LED: See meanings in the following
table.
English
Output
(Red)
On
On
Off
Refer to the
Off
Blink
E. Internal / External air selection :
This switch determine the air supply. With the "In
Compr" position selected, the machine operates
through the built-in compressor. With the "Ext Air"
position
completely disabled and the machine operates
through an external air supply hose connected to the
proper air inlet connection placed on the machine
rear side.
If operate with external air, be sure to select the "Ext Air"
switch position in order to completely disable the built-in
compressor.
damaged by the probable greater pressure of the
external air.
F.
Air Pressure Gauge and Regulator Knob :
Allow to regulate and monitoring the air pressure.
8
LEDs
Thermal
(Yellow)
Off
The cutting torch is energized.
On
Part in place error: the retaining
cap is not properly screwed.
To restore the machine:
Screw firmly the torch retaining
cap.
Wait for 5seconds; during this
time the Output and Thermal
LEDs blinks alternately.
After 5seconds the machine is
automatically
ready to operate.
On
The machine is overheated and the
output has been disabled.
usually occurs when the duty cycle
of
the
machine
exceeded. Leave the machine On
to allow the internal components to
cool. When the thermal LED turns
off, normal operation is again
possible.
Blink
Mains undervoltage or overvoltage
error:
the machine is disabled.
When the mains return in the
correct range, the machine restart
automatically.
Off
Low air pressure error.
To check / adjust the air pressure
(see recommended values in the
Tecnical
Specifications
manual):
Put the machine in Purge mode
[A].
Check
pressure
manometer and air pressure
regulator knob [F].
If necessary, check and adjust
also the inlet air pressure
through the commands of the
external compressor.
selected,
the
internal
WARNING
Otherwise the compressor may be
Meaning
restored
and
This
has
been
of
this
and
adjust
the
air
through
the
compressor
is
English