Malfunction
Fault message "Suction
Side" appears
Fault message "TOP UP 1.5
BAR" appears.
10 STORAGE
1. Drain suction and pressure line.
2. Unscrew drain plug and allow the water to
drain out of the pump.
3. Screw in the drain plug again and store pump
and accessories in a frost-proof place.
NOTE If there is the danger of frost, the sys-
tem must be completely drained and the pump
must be stored in a frost-proof place.
11 DISPOSAL
Electrical and electronic appliances do not
belong in household waste, but should be
collected and disposed of separately.
13 WARRANTY
We will remedy any material or manufacturing defects discovered in the device during the statutory
period of limitation for claims for defects by repair or replacement at our discretion. The period of lim-
itation is determined in each case by the law of the country in which the device was purchased.
Our warranty promise applies only if:
These operating instructions are observed
The device is handled correctly
Original spare parts have been used
24
Possible cause
The suction line is not in the
water.
Blockage on the suction side.
Pressure line closed off.
Pump drawing air into the suc-
tion line.
Pump drawing air, water short-
age on suction side.
Hose diameter too small.
Water volume on the suction
side to little
Low air pressure in the storage
vessel.
The warranty becomes void in the case of:
Remedy
Submerge the end of the suction line
into the water by min. 30 cm.
Remove dirt from the suction area
and filter.
Open the closing off devices in the
pressure line.
Check all the connections in the suc-
tion line for leaks.
Replace seal ring.
Switch pump off and allow to cool.
Replace the pressure hose with one
with a larger diameter.
Throttle back the pump to adapt the
flow rate.
Top up the air in the storage vessel.
(Set the diaphragm pressure to 1.5
bar).
Running text: TOP UP 1.5 BAR
Packaging, equipment and accessories are made
from recyclable materials, and must be disposed
of accordingly.
12 AFTER-SALES/SERVICE
In the event of questions of warranty, repair or
spare parts, please contact your nearest AL-
KO Service Centre. These can be found on the
Internet at:
www.alko-garden.com/service-contacts
Further information on spare parts can be found
at:
www.alko-garden.com/spareparts
Unauthorised repair attempts
Unauthorised technical modifications
Use for other than the intended purpose
HW 5000 / 6000 FMS Premium
Storage

Werbung

loading

Diese Anleitung auch für:

Hw 6000 fms premium