Maintenance and care
8 MAINTENANCE AND CARE
8.1
Check the air pressure in the storage
vessel
NOTE Check the air pressure in the storage
vessel at regular intervals. It must not exceed 1.5
bar (see Section "Commissioning: Checking the
Air Pressure in the Storage Vessel").
NOTE If the display shows the information
ALARM and REFILL 1.5 BAR, air has to be
topped up in the diaphragm storage vessel.
When the correct pressure is reached, the dis-
play shows ALARM and AIR PRESSURE OK.
8.2
Cleaning the pump
NOTE After conveying swimming pool water
containing chlorine or fluids that leave residues,
the pump must be flushed out with clear water.
1. Disconnect the pump from the mains supply
and secure to prevent restarting. The pump
stops automatically.
2. Flush the pump with clear water.
3. Insert the mains plug into the power socket.
4. Turn on the pump at the on / off switch. The
pump starts automatically.
8.3
Clean the filter
1. Unscrew filter chamber drain plug (9), drain
the filter chamber and screw in the drain plug
again.
2. Unscrew transparent filter cover (1) using fil-
ter wrench (18).
3. Remove filter (19/20) from filter housing (2)
and clean under running water.
4. Clean filter housing and transparent filter cov-
er.
5. Before installing the filter, check filter seals
(19) and housing seal (23) for damage and
replace, if necessary.
6. Install the filter, screw on the transparent filter
cover and tighten finger-tight using the filter
wrench.
Malfunction
Motor does not run.
467777_h
Possible cause
No mains power.
8.4
Cleaning the check valve
1. Remove the filter (see Section "Cleaning the
filter").
2. Unscrew check valve (21) and clean under
running water.
3. Replace seal (22), if necessary.
4. Fit check valve.
5. Install filter.
8.5
Clean float
1. Unscrew pressure line (11) with elbow nipple
(13) and connecting nipple (15).
2. Unscrew screw-in nipple (24) with seal (25).
Note the installation position of the float. Pull
out the float body and clean it.
3. Install the float again - noting the installation
position (Fig. D).
8.6
Remove blockages
1. Disconnect the pump from the mains supply
and secure to prevent restarting.
2. Disconnect the suction line from the pump in-
let.
3. Connect pressure line to the water line.
4. Allow water to run through the pump housing
until the blockage is removed.
5. Switch on the pump briefly to check that it
runs smoothly.
9 HELP IN CASE OF MALFUNCTION
DANGER! Danger of electric shock!
There is a risk of electric shock when working on
the pump.
Disconnect the mains plug before starting
any fault remedying work.
Faults in the electrical system must be recti-
fied by a qualified electrician.
NOTE In the event of faults that you cannot
rectify, please contact our Customer Service de-
partment.
Remedy
Check fuses, have the power supply
checked by a qualified electrician.