Display indications
Display
7.2
Additional functions
Display
467777_h
Switching condition
Pump does not switch
on after self-test. In op-
eration mode, the pump
does not switch on.
After 90 seconds dry
running, the pump
switches off.
Pump running.
Pump switches off.
Pump switches on.
Switching condition
Pump running.
Pump running.
Pump running.
Pump running or
switched off.
Function / action
Top up with air and then press the SET button. Carry
out the initial commissioning again. Air pressure, see
"Technical data".
Running text: TOP UP 1.5 BAR
Check the suction line and then press the SET but-
ton. Carry out the initial commissioning again.
Running text: CHECK WATER INFEED
Pump delivering water. Storage vessel being filled.
Part of the water is being drawn off.
Pump has achieved the set switch-off pressure.
Pump has achieved the set switch-on pressure.
Function / action
Flow rate: Press the MODE button until the flow rate
appears.
Running text: FLOW RATE
Total water quantity pumped: Press the MODE
button. Displays the volume of water already
pumped. Rest not possible.
Running text: TOTAL VOLUME
Part volume: Press the MODE button. Displays the
part volume of water already conveyed. Reset. Hold
the SET button pressed for approx. 3 seconds.
Running text: PART VOLUME
Push the MODE button several times until ECO X
MODE appears on the display. Now the pump
switches off earlier (energy-saving mode). See
"Commissioning".