Herunterladen Diese Seite drucken

Seav LRX 2102 NEW Bedienungsanleitung Seite 9

Elektronische schalttafel

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
follows: using the SEL key to move to the flashing T.
PAUSA LED, press the SET key briefly, then wait for the
amount of time you wish to set for automatic closing;
briefly press the SET key again, and in that moment the
automatic closing time will be memorised and the T.
PAUSA LED will stay on steady.
initial condition (without automatic closing), move to the
flashing T. PAUSA LED, then press the SET key twice within 2
seconds. The Led will switch off and the operation will be
finished.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
EXTENDED MENU 1
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
If you wish to enable the functions described in Extended
Menu 1, proceed as follows: press and hold the SET button for
5 seconds, after which amount of time the T. MOT. PED and T.
PAUSA LEDs will start flashing alternately. The user then has
30 seconds to select the functions for Extended Menu 1 from
the SEL and SET buttons. After another 30 seconds the
control unit will go back to the main menu.
----------------------
EXTENDED MENU 1
Led Reference Led Off Led On
A) CODE
Step-by-Step
B) CODE PED
Electronic Brake = OFF
C) IN.CMD.AP. Dead man=OFF
D) LAMP/CORT
Deceleration = OFF
E) PGM. AUT
Follow Me = OFF
F) T.MOT
Remote PGM = OFF
G) T. MOT.PED
Alternate ON/OFF flashing light
H) T. PAUSA
Alternate ON/OFF flashing light
A) CODE (
Step-by-Step / Automatic Operation
The control unit is supplied by the manufacturer with Automatic
mode disabled. If you wish to enable the function, proceed as
follows: make sure that you have enabled extended menu 1
(reported by alternately flashing T. MOT PED Leds and T.
PAUSA Led), by using the SEL key to select the flashing
CODE LED, and then press the SET key. At this point the
CODE LED lights up steady and programming is finished.
Accordingly, using either the radio-control or the low voltage
push button panel to operate the gate, you will obtain the
following function: the first impulse controls opening until the
motor time expires, the second impulse controls gate closing. If
an impulse is sent before the motor time expires, the control
unit changes the direction of motion in the opening and closing
phases. Repeat the procedure if you wish to restore the
previous configuration.
B) CODE PED ( Electronic Brake ) :
The control unit is supplied by the manufacturer with the
electronic brake function disabled. If you wish to enable the
function, proceed as follows: check that Extended Menu 1 is
enabled (T. MOT. PED and T. PAUSA LEDs start flashing
alternately), use the SEL button to move to the flashing PED
CODE LED then press the SET key: at that point the PED
CODE LED will light up steady and programming is complete.
Accordingly, the control unit slows down gate advancement by
inertia, when there is a stop or command to change the
direction of motion. Repeat the procedure if you wish to restore
the previous configuration.
C) IN. CMD. AP. ( Anti-collision Function ) :
The control unit is supplied by the manufacturer with the Anti-
collision (pedestrian) Function disabled. If you wish to enable
the function, proceed as follows: check that Extended Menu 1
If you wish to restore the
-----------------
Inverting
Electronic Brake= ON
Dead man APCH or CH=ON
Deceleration = ON
Follow Me = ON
Remote PGM = ON
) :
is enabled (T. MOT. PED and T. PAUSA Leds flash
simultaneously), use the SEL button to move to the flashing IN.
CMD. AP. LED and then press the SET button. At this point
the IN. CMD. AP. LED will light up steady and programming is
complete. The control unit will now operate in Anti-Collision
(pedestrian) mode.
If you wish to enable the Anti-Collision (pedestrian) function for
the closing phase only, repeat the operation described above,
pressing the SEL key twice (making the IN.CMD.AP. LED flash
quickly). Repeat the procedure if you wish to restore the
previous configuration.
D) LAMP/CORT ( Deceleration ):
As mentioned above, it is possible to programme a
deceleration phase on the control unit for opening or closing,
whereas deceleration is automatically enabled with the
Automatic Programming function. If you do not wish to
implement any deceleration, it can be excluded: therefore, if
you are using Automatic Programming, the Deceleration phase
will not be enabled, whereas if you are using Motor Time
Programming, as you are programming you will not be given
the possibility of programming deceleration during the opening
and closing phases. If, prior to excluding deceleration, it was
programmed from the Motor Time Programming function, it will
be necessary to repeat programming all over again. If you wish
to exclude deceleration, proceed as follows: make sure
Extended Menu 1 is enabled (reported by T.MOT.PED and T.
PAUSA Leds flashing alternately). Using the SEL key, move to
the flashing LAMP/CORT. LED and then press the SET key:
the LAMP/CORT. will turn off definitely and programming will
be complete. Repeat the procedure if you wish to restore the
previous configuration.
E) PGM. AUT ( Follow Me ) :
It is possible to set the "Follow Me" function on the control unit:
this function can only be programmed if a Pause Time has
already been programmed, and it is used to shorten the Pause
time to 5 sec after the photocell disengages, i.e. the gate
closes 5 seconds after the user has passed through. If you
wish to enable the function, proceed as follows: check that
Extended Menu 1 is enabled (T. MOT. PED and T. PAUSA
Leds flash simultaneously), use the SEL button to move to the
flashing PGM. AUT. LED and then press the SET key: the
PGM. AUT. LED
will light up steady and programming is
complete. Repeat the procedure if you wish to restore the
previous configuration.
F) T. MOT (Remote programming of radio control):
The control unit allows the transmission code to be
programmed by remote, without using the SEL key.
To programme the transmission code from remote proceed as
follows: send the radio control code continuously for more than
10 seconds and the control unit will enter the programming
mode as described above for the CODE LED in the main
menu.
The control unit is supplied by the manufacturer with remote
programming of the transmission code not enabled; to enable
the function proceed as follows: check that the extended menu
1 is enabled (the T. MOT. PED and T. PAUSA LEDs start
flashing alternatively), use the SEL key to navigate to the
.T:MOT LED when the corresponding LED is flashing and
press the SET key: the T.MOT LED is enabled and
programming is complete. Repeat the operation to restore the
previous configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
If you wish to enable the programming of the deceleration
power carried out by the control unit, proceed as follows:
access Extended Menu 1 (as described in the relative
paragraph), then press and hold the SET button down again

Werbung

loading