ELECTRONIC CONTROL UNIT
LRX 2102 NEW
Single-phase electronic control unit for the automation of
sliding gates with incorporated radio receiver.
- Mod. LG 2102R NEW
- Mod. LRS 2102 NEW
- Mod. LRS 2102 NEW SET
- Mod. LRH 2102 NEW
I
MPORTANT FOR THE USER
- The device can be used by children over 8 years of
age and persons with reduced physical or psychological
abilities or with little knowledge and experience only if
supervised or educated in its operation and safe use, in
order to also understand the dangers involved in its use.
- these instructions are also available at the website
www.seav.com
- Do not allow children to play with the device and keep
the radio controls away from their reach.
- Frequently examine the system to detect any signs of
damage. Do not use the device if it is in need of repair
work.
-Always remember to disconnect the power supply
before carrying out any cleaning or maintenance.
- Cleaning and maintenance must not be carried out by
unsupervised children
- ATTENTION: keep this instruction manual safe and
observe the important safety requirements contained
herein. Failure to comply with the requirements may
cause damage and serious accidents.
I
the
MPORTANT FOR
INSTALLER
16) Before automating the gate, check that it is in good
conditions, in compliance with the Machinery Directive
and with EN 12604.
17) Check that the location where the installation is
located enables compliance with operating temperature
limits specified for the device.
18) The safety of the final installation and compliance
with all prescribed Standards (EN 12453 - EN 12445) is
the responsibility of the person who assembles the
various parts to construct a total closing.
19) It's recommended to use safety devices with a
connection self test.
20) Once installation is finished, it is recommended that
all necessary checks be performed (appropriate
programming
of
the
installation of safety devices) to ensure that compliant
installation has been performed.
21) Fix the control unit to the wall using the appropriate
support. This support should be facing downwards:
insert the screws in the spaces provided.
22) The control unit does not have any type of isolating
device for the 230 Vac line. It is therefore the
responsibility of the installer to set up an isolating
device inside the system. It is necessary to install an
omnipolar switch, surge category III. It must be
positioned to provide protection from accidental closing,
pursuant to point 5.2.9 of EN 12453.
: Without radio receiver
: 433.92 MHz
: 433.92 MHz "narrow band"
: 868.3 MHz "narrow band"
control
panel
and
correct
GB
Cables for power and connection to the motor suitable
for insertion in the pg9 cable glands provided must have
an outside diameter between 4.5 and 7 mm. The
internal conductor wires must have a nominal section of
0.75mm2. If a raceway is not used, use H05RR-F
cables. Pay careful attention when fastening the cables
so that they are anchored in a stable manner.
Furthermore, care is required when drilling holes in the
outside casing where connecting and power supply
cables will pass, and when assembling the cable
glands, so that everything is installed so as to maintain
the panel's IP protection characteristics.
8) Cables for power and connection to the motor
suitable for insertion in the pg9 cable glands provided
must have an outside diameter between 4.5 and 7 mm.
The internal conductor wires must have a nominal
section of 0.75mm2. If a raceway is not used, use
H05RR-F cables. Pay careful attention when fastening
the cables so that they are anchored in a stable
manner. Furthermore, care is required when drilling
holes in the outside casing where connecting and power
supply cables will pass, and when assembling the cable
glands, so that everything is installed so as to maintain
the panel's IP protection characteristics.
9) The gearmotor used to move the frame must comply
with that prescribed at point 5.2.7 of EN 1245
10) In compliance with 5.4.2 of EN 12453, it is
recommended to use gearmotors equipped with an
electric-mechanical release device, so that the door can
be moved manually in case of necessity.
11) In compliance with 5.4.3. of EN 12453, use electric-
mechanical release systems or similar devices which
stop the door safely in the end run position.
12) The various electrical components external to the
control unit must be cabled in accordance with standard
EN 60204-1 as amended, and as set forth in point 5.2.7
of EN 12453. Power cables may have a maximum
diameter of 14 mm.
must be fixed using the cable glands provided.
13) The assembly of a push button panel for manual
control must be completed positioning the push button
panel in such a way that the user is not placed in a
dangerous position.
14) The safety function ensured by the control unit is
active only during closing, therefore, protection on
opening must be ensured in the installation phase with
measures (guards or safety distances) independent of
the control circuit.
15) For proper functioning of the radio receiver, if using
one or more control units, the installation at a minimum
distance of at least 3 metres one from the other is
recommended.
LG 2102 NEW - LRS 2102 NEW
LRS 2102 NEW SET - LRH 2102 NEW
comply with the requirements of Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.
Power supply and connection cables
The below products:
Electronic Control Unit:

Werbung