TECHNICAL DATA:
- Power supply
- Flashing beacon output
- Motor output
- Auxiliary power output
- Stop limit and low voltage commands : 24 Vcc
- Working temperature
- Radio receiver
- Op. transmitters
- Max stored TX codes
- Box dimensions
- Container
TERMINAL BOARD CONNECTIONS:
CN1:
1 : 230 V ac line input (Phase).
2 : 230 V ac line input (Neutral).
3 : 230 V ac flashing line input (Neutral).
4 : 230 V ac flashing line input (Phase).
5 : Opening motor output.
6 : Common motor output.
7 : Closing motor output.
CN2:
1 : Service power supply output 24Vac 6 W.
2 : Service power supply output GND.
3 : Open-close command button input (NA).
4 : Common GND input.
5 : Safety device input (NC).
6 : Opening stop limit input (NC).
7 : Common GND input.
8 : Closing stop limit input (NC).
9 : Earth antenna input.
10: Antenna hot pole input.
: 230 Vac 50/60Hz 900W(4A) max.
: 230 Vac 50/60Hz
100W Resistive Load max.
50W Inductive Load max.
: 230 Vac 50/60Hz 750 W max.
: 24 Vac 3 W max.
: -10 ÷ 55 °C
: see model
: 12-18 Bit or Rolling Code
: 120(CODE + CODE PED)
: 110x121x47 mm.
: ABS V-0 (IP54).
OPERATING FEATURES:
Step-by-step operation:
By using either the radio-control ( CODE led on ) or the low
voltage buttons to activate the gate, you obtain the following
action:
the first impulse activates the opening mechanism until the
motor time expires or the opening limit switch is reached, the
second impulse closes the gate. If an impulse is sent before
the motor time expires or one of the two end runs are reached,
the control unit will stop both opening and closing movements.
An additional control re-starts motion in the opposite direction.
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
The choice of this operating mode is described in the
instructions for setting the delay period.
Pedestrian Passage:
The control unit allows, using either the radio-control (
CODE PED led on) or the Pedestrian button, the Motor
to run for a programmable amount of time.
Photocells:
The control unit allows Photocells to be powered and
connected in accordance with directive EN 12453.
- DS Input (NC)
Photocell operation is ignored during opening, whereas during
closing they will reverse the direction of movement.
Opening and Closing Limit Switch:
The control unit allows the Opening and Closing Limit Switch
connection (NC). When it is triggered during the respective
operating phases, movement stops immediately.
If not used, this input must be bridged.
Motor Power and Speed adjustment:
The electronic control unit is equipped with a VR1 trimmer to
adjust motor Power and Speed, fully managed by the
microprocessor. The adjustment can be made within a range
of 50% and 100% of the Maximum Power.
Nevertheless, every movement has an initial surge, powering
the motor for 2 seconds at the maximum power even if motor
power adjustment is enabled.
Attention: You will need to repeat the teach-in phase if you
wish to adjust the VR1 trimmer as operation and deceleration
times may be affected.
Deceleration:
The motor deceleration function is used on the gates to stop
them from reaching their final position at a high speed in the
opening and closing phases.
The control unit allows deceleration to be programmed for the
desired points (before the gates are completely open or
closed) during Motor Timer programming (see Main menu).
If you are using the "Automatic programming" function (see
menu 2) it is also possible to include a deceleration phase (see
Main menu).
Operation with TIMER:
The control unit can have a timer set up instead of an open-
close control button.
Example: at 08:00 the timer closes the contact and the control
unit opens the gate. At 18:00 the timer opens the contact and
the control unit closes the gate. During the interval between
08:00 and 18:00, at the end of the opening phase, the control
unit disables the flashing beacon, automatic closing and radio
controls.