for 5 seconds, after which amount of time the T. MOT. PED
and T. PAUSA LEDs will flash simultaneously. The user then
has 30 seconds to select the deceleration power using the SEL
and SET buttons. After, another 30 seconds the control unit
will go back to the main menu.
----------------------
EXTENDED MENU 2
Level
Leds On
1
CODE
2
CODE – CODE PED.
3
CODE – CODE PED – IN.CMD.AP.
4
CODE – CODE PED – IN.CMD.AP. – LAMP/CORT
5
CODE – CODE PED – IN.CMD.AP. – LAMP/CORT – PGM.AUT
6 CODE – CODE PED– IN.CMD.AP. – LAMP/CORT – PGM.AUT – T.MOT
Deceleration Programming
The control unit allows you to programme the power used to
carry out the deceleration phase.
It is possible to choose between 6 different levels of power:
every combination of lit Leds corresponds to a level according
to the table above; in other words, starting from the lowest led
(LED CODE) and moving upwards, each Led corresponds to a
higher power level. Using the SEL key it is possible to scroll
through the different power levels; for every selected power
level, the highest respective Led will flash (for example, if level
4 is selected the CODE, CODE PED. and IN.CMD.AP. leds
light up steady, whereas the LAMP/CORT led will flash); press
SET to confirm.
Level 3 is selected in the default configuration.
RESET :
To reset the default configuration of the control unit, press the
SEL and SET buttons simultaneously; all RED signal Leds will
switch on and then immediately off again.
DIAGNOSTICS :
Control input test:
On each low voltage control input, the control unit uses a LED
signal to make the status readily known.
Operating logic: when a LED is on it means the input is closed,
when a LED is off it means the input is open.
LED MANAGEMENT :
After 3 minutes of inactivity in the programming procedure,
there is the automatic shutdown of
savings. A single press of the SEL or SET key, or a movement
command will activate the LED light up according to settings
programmed previously.
-----------------
the Leds
for energy

Werbung