PROGRAMMING :
The SEL key: this selects the type of function to be
memorised, which is indicated by a flashing Led.
Repeatedly press the key to select the desired function. The
selection will remain active for 10 seconds, indicated by a
flashing Led. If no other operations are carried out during this
time, the control board will return to its previous state.
The SET key: this programs the information according to the
type of function previously selected with the SEL button.
IMPORTANT: The SET key function can also be replaced by
the radio-control, if previously programmed (CODE led on).
MAIN MENU
The control unit is provided by the manufacturer with the
possibility of selecting a number of important functions.
---------------------- MAIN MENU -----------------
Led Reference Led off Led On
1) CODE
No code
2) CODE PED.
No code
3) IN.CMD.AP.
Disabled
4) LAMP/CORT
Flashing
5) PGM. AUT
PGM Automatic=OFF
6) T. MOT.
Motor time 30 sec.
7) T.MOT.PED Mot. Time Ped. 10 sec.
8) T. PAUSA
No auto close
1) CODE: (Radio-control code)
The control unit allows up to 120 radio-controls to be
memorised with different types of fixed or rolling codes.
Programming.
The transmission code is programmed in the following way:
use the SEL key to move to the flashing CODE LED, at the
same time send the pre-selected code from the radio-control
you wish to use; when the CODE LED stays on steadily,
programming is finished. If all 120 available codes have been
memorised, by repeating the programming operation, all
programming LEDs will start to flash, indicating that it is not
possible to memorise any more codes.
Deletion.
Memorised codes can be deleted in the following way: press
the SEL key, the CODE LED will start flashing, then press the
SET key, the CODE LED will switch off and the procedure is
finished.
2) CODE PED:(Code for the Ped./ S Door radio-control)
The programming and deleting procedure is the same as
the one illustrated above except that the selected Led
should be for PEDESTRIAN CODE.
3) IN. CMD. AP.: (Command inhibition during opening and
pause time, if entered)
The command inhibition function during opening and pause
time, if entered, is used when automation includes a loop
detector. During the opening or pause phase the control unit
does not consider the commands sent by the loop detector
with every passage.
The factory settings of the control unit have disabled command
inhibition during opening and pause time. If it is necessary to
enable it, do the following: use the SEL key to move to the
flashing IN.CMD.AP LED then press the SET key. The
IN.CMD.AP LED will light up steady. Repeat the procedure if
you wish to restore the previous configuration.
4) LAMP/CORT. : (Selection of the flashing light or the
courtesy light)
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light.
The control unit is supplied by the manufacturer with the
Flashing function enabled. If you wish to enable the flashing
Code entered
Code entered
Enabled
Courtesy Light
PGM Automatic=ON
Programmed time
Programmed time
With auto close
beacon function, including during pauses, proceed as follows:
using the SEL key to move to the LAMP/CORT flashing LED
then press the SET key, and the LAMP/CORT flashing LED
will switch on steady.
Repeat the operation if you wish to restore the factory setting.
If you wish to enable the courtesy light, repeat the operation
described above, pressing the SEL button twice instead of
once (making the LAMP/CORT LED flash rapidly). Repeat the
operation if you wish to restore the factory setting.
5) PGM. AUT. : (Automatic Programming):
With this control unit it is possible to carry out Automatic
Programming ( SIMPLIFIED).
First, move the gates to their half-way position, press the SEL
button until the PGM. AUT. LED flashes and then press and
hold the SET button down. The control unit completes the Auto
programming phase by executing a complete opening and
closing phase (hold the SET key down until Auto Programming
is finished). At the same time, the Deceleration cycle is
automatically configured at 15% of the complete cycle.
During Automatic Programming, you can use the radio-control
key on the control unit instead of the SET key, only if
previously memorised.
6) T. MOT and DECELERATION:
operation time of max 4 minutes)
The control unit is factory supplied with a predefined motor
operating time of 30 sec. without deceleration.
If it is necessary to modify the motor operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT LED,
then press the SET key briefly. The Motor will begin its
opening cycle. When it starts the initial point of deceleration,
press the SET key again. At the same time, the motor will
decelerate until it reaches the required position. Press the SET
key to finish the opening cycle. The T. MOT LED will then start
flashing quickly. Now repeat motor time programming and the
deceleration operation for the closing cycle. If you do not want
the control unit to decelerate, when the opening and closing
phase
is
finished,
press the
programming, instead of just once.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
7) T. MOT. PED:
(Programming a pedestrian operating time of 4
minutes max.)
The control unit is factory supplied with a predefined
Pedestrian
Motor
operating
deceleration.
If it is necessary to modify the pedestrian operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT PED.
LED, then press the SET key briefly. The Motor will start the
Opening cycle; press the SET key again at the point where you
wish to start deceleration: the T. MOT. PED. LED will start
flashing at a slower rate and the Motor will decelerate; when it
reaches the required point, press the SET key to finish the
Opening cycle. At this point the T. MOT PED. LED will start
flashing at its standard pace again and the Motor will begin the
Closing phase; repeat the above operations for the Closing
phase.
If you do not want the control unit to decelerate, when the
opening and closing phase is finished, press the SET key twice
during programming, instead of just once.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
8) T. PAUSA :
(Automatic closing time programming max. 4
minutes)
The control unit is factory supplied without automatic closing.
you wish to enable automatic closing, proceed as
(Programming a motor
SET
key twice
during
time
of
10
sec.
without
If

Werbung

loading