Désignation individuelle
1. Entrée type T1 K
2. Entrée type T1 K
(seulement pour K102)
3. Ecran LCD
4. Touche Marche/Arrêt
5. Touche « Min/Max »
Ecran à cristaux liquides (LCD)
26
6. Touche « Hold »
7. Touche « Relatif »
8. Commutation de °C / °F
9. Vis de calibrage offset
10. Logement des piles
read the current temperature in the background. To deactivate the
Data-Hold function, press the hold button (6) once again – the hold
H
symbol "
" (1) will be extinguished. In the LCD display the current
temperature will now be displayed.
Note: When the Data-Hold function is activated, the Relative and
MIN/MAX functions as well as the °C/°F switch are no longer acces-
sible.
Relative function
The hand thermometer is equipped with a Relative function. By
pressing the ∆ Rel-button (7) the hand thermometer will register the
temperature at the pressing of the ∆ Rel-button (7). The difference
between the temperature readings will be indicated in the LCD dis-
play. To deactivate the relative function, press the ∆ Rel-button (7)
once again.
Max/Min function
The hand thermometer is equipped with a Max/Min function. This
function records the lowest (Min) and the highest (Max) tempera-
tures during the measurement. As a result processes can be easily
monitored. By pressing the Max/Min button (5) you will reach the
Max/Min function. Through repeated pressing of the Max/Min but-
ton (5) you can scroll though the various temperatures
(Min/Max/Current).
When "MAX" (3) is displayed, the highest temperature recorded will
be shown, when "MIN" (2) is displayed, the lowest. When "MAX
MIN" blinks simultaneously in the LCD display, the current temper-
ature will be shown – the maximum and minimum temperature val-
ues will however continue to be updated and recorded.
To leave the Min/Max function press and hold the Max/Min button
for approximately two seconds.