Herunterladen Inhalt Inhalt Diese Seite drucken

17- Technical Features - Bpt TH 400 Gebrauchsanweisung

Programmierbarer raumthermostat thermoprogram
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WARNING. Inserting the batteries
the wrong way round can damage
the thermostat.
The use of low batteries can also
give rise to faulty thermostat ope-
ration, in which case, you should
proceed as explained in chapter
14.
17 - TECHNICAL FEATURES
Equipment for civilian use.
• Independently-installed electro-
nic device.
• LCD graphic display.
• Power supply: three LR03, type
AAA, 1.5V alkaline batteries.
• Battery life: over one year.
• Battery low indication.
• Time available for replacing bat-
teries: about 2 min.
• Relay: max voltage 250V, max
current 5A for resistive loads (2A
for inductive loads).
• Type of action: 1 B-U.
28
GB
• Contacts available: 1 NO-NC
switching contact.
• Four operating modes: AUTO-
MATIC, MANUAL, ANTIFREEZE,
STAND-BY.
• Selection of programs: HEA-
TING, COOLING, WILD CARD.
• Plant running time counter: from
1 to 9,999 hours.
• Option for timer-controlled ma-
nual, antifreeze and stand-by
functions (up to 99 hours or
days).
• Range of application: from +2 °C
to +35 °C.
• Temperature levels: three, pro-
grammable between +2 °C and
+35 °C.
• Antifreeze temperature: adjusta-
ble from +2 °C to +35 °C.
• Programming: one temperature
level per hour for each day of the
week.
• Room temperature detection
rate: every 15 s.
• Temperature threshold: program-
mable from ±0.1 °C to ± 0.9 °C.
• Reading resolution: 0.1 °C.
• Precision: ≤ ± 0.3 °C.
• Class A software.
• Pollution level: 2.
• Impulse voltage: 4 kV.
• Max temperature of control
head: 40 °C.
• Insulation grade: IP30.
• Working temperature range:
from 0 °C to +40 °C.
• Overall sizes: 116x80x21 mm.

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis